Measurement and Control Products for WEATHER Measurement and Control Products for WATER Measurement and Control Products for ENERGY Measurement and Control Products for MACHINES Measurement and Control Products for STRUCTURES Measurement and Control Products for EARTH
High Accuracy and Precision
Designed for long-term monitoring
 
 
 
 
 
Image Gallery

General Support

User Forum

Visit the Campbell Scientific Forum to submit your question to users around the world.

Ask an Expert

Ask a Question using our simple form and we'll pass it along to one of our experts.

Call Us

Our Application Engineers are ready to answer your questions. Our support numbers are:

Technical Support
US Sales
International Sales
Order Entry
Accounts Receivable
Repairs
435.227.9100
435.227.9120
435.227.9140
435.227.9090
435.227.9092
435.227.9105

Downloads

There are currently no Downloads for the CS616-L.

FAQ

Q. What makes the CS616 an improved sensor over the CS615?
  • The CS616 meets European noise emission standards, which are stricter than US standards.
  • The CS616 period output is more linear than the CS615 output.
  • The CS616 will operate over a wider range of soil types than the CS615.
  • We can still obtain all of the parts to build the CS616.
..more
Q. Why doesn't the CS616 work with the 21X?

The CS616 has a faster period output than the CS615, so it will not work with the 21X dataloggers.

..more
Q. I have a CS615 water content reflectometer. I would like to cut the rods so that it will fit in my container. Can I do that?

If CS615 rod length is reduced, the response of the probe to water content will change, and the recommended calibration is no longer valid. Additionally, reducing rod length will adversely affect the water content measurement resolution. However, the CS615 will respond in a similar manner to the response with standard length rods (30 cm). The response needs to be described for the modified probe to generate a calibration. CS615 water content resolution is better than 0.2% volumetric water content with 30 cm rods. If the rods are cut by 15 cm, water content resolution will be between 1% and 2%. A few additional points are:

  • Probes with rods less than 15 cm may be unstable.
  • A calibration of CS615 output to volumetric water content will have to be established using field or laboratory measurements. Field calibration measurements can be made by recording the CS615 period with the probe in soil, removing the probe and taking samples of known volume for use with gravimetric water contents.
  • Water content measurement resolution will be affected.
  • Cutting the rods will void their warranty.