Measurement and Control Products for WEATHER Measurement and Control Products for WATER Measurement and Control Products for ENERGY Measurement and Control Products for MACHINES Measurement and Control Products for STRUCTURES Measurement and Control Products for EARTH
Wider Pressure Range
Resides inside weatherproof enclosure
CS106 Pricing Details
Educational Discounts: Yes    Quantity Discounts: Yes    Restockable: Yes    Warranty: 3 year   
Model Description
CS106 Vaisala PTB110 Barometer (500 - 1100 hPa), 30 inch cable
Common Accessories
CABLE5CBL-L 5-Conductor 22AWG Cable w/Drain
The CABLE5CBL-L is used when the barometer and datalogger are housed in different enclosures. This 24-AWG, five-conductor cable has a Santoprene® jacket and an aluminum mylar shield.
CABLE5CBL-L Options (hide details)
-L ft per cable
The CABLE5CBL-L is used when the barometer and datalogger are housed in different enclosures. This 24-AWG, five-conductor cable has a Santoprene® jacket and an aluminum mylar shield.
Cable Termination Options (hide details)
-PT -PT w/Tinned Wires
The CABLE5CBL-L is used when the barometer and datalogger are housed in different enclosures. This 24-AWG, five-conductor cable has a Santoprene® jacket and an aluminum mylar shield.
-PW -PW w/Pre-Wire Connector
The CABLE5CBL-L is used when the barometer and datalogger are housed in different enclosures. This 24-AWG, five-conductor cable has a Santoprene® jacket and an aluminum mylar shield.
ENC100 Barometer Enclosure
The ENC100 is available for housing the barometer in its own enclosure. It includes a backplate, compression fitting, vent, and mounting bracket.
Replacement Parts
16004 5-pin Screw Terminal Plug Connector 3.5MM pitch Straight Wire Entry Black
This terminal block plugs into the CS106 to provide connection terminals for the sensor leads coming from the datalogger.
21819 Connector Coding Key Weidmuller 1693430000
The 21819 inserts into the 16004. The 21819 helps prevent customers from plugging the 16004 connector in upside down. Plugging it in upside down will damage the barometer—perhaps beyond repair. The 21819 will key two of the 16004 connectors.
Services
16085 Barometer Recalibration w/ Documentation
Campbell Scientific offers recalibration service for this barometer. Factory recalibration requires an RMA (Returned Material Authorization). The barometer is recalibrated to meet original specification, if possible.The price listed above is for recalibration only; it does NOT include any repairs to damaged or malfunctioning sensors.

Resources and Links

Ships With

(1) NIST Traceable Calibration Certificate

(1) Sensor cable, 2.5 ft

(2) 505 Screws

(2) 6044 Grommets