Measurement and Control Products for WEATHER Measurement and Control Products for WATER Measurement and Control Products for ENERGY Measurement and Control Products for MACHINES Measurement and Control Products for STRUCTURES Measurement and Control Products for EARTH
Fast, Compact Datalogger
Supports complex installations, built-in keyboard and display
 
 
 
 
 
Image Gallery
CR3000 Pricing Details
Educational Discounts: Yes    Quantity Discounts: Yes    Restockable: Yes    Warranty: 3 year   
Model Description
CR3000 Micrologger (R)
Temperature Ranges (hide details)
-ST -ST Tested -25 to +50C
Every CR3000 is tested and guaranteed to perform within published specifications over the standard temperature range.
-XT -XT Tested -40 to +85C
For extended temperature range testing, analog accuracies are derated approximately two times over published specifications.
Warranty Lengths (hide details)
-SW -SW Standard 3yr Warranty
At the time of purchase, the CR3000 includes a standard warranty of 36 months. See our full warranty policy in the CR3000 manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our extended warranty adds 48 months to the standard 36-month warranty, bringing the total warranty period to 84 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
Base & Power Options (hide details)
-NB -NB Base with No Battery
Base without battery is for applications where user-supplied batteries are used.
-ALK -ALK Base w/Alkaline Batt
The alkaline base includes ten alkaline D cells. Operating temperature range is -25° to +50°C.
-RC -RC Rechargeable Base
The rechargeable base option provides two 6-V, 7-Ahr sealed rechargeable batteries that can be trickle-charged via vehicle power (requires DCDC18R), solar panels (typically SP10 or SP20), or ac power (requires 9591 or 14014 transformer). Operating temperature range is -40° to +60°C.
Calibration Certificate (hide details)
-NC -NC No Calibration Cert
The CR3000 is shipped without a calibration certificate.
-CC -CC Calibration Cert
When this option is chosen, a two-page calibration certificate is shipped with the CR3000. If you are using the 21852 A2LA/NVLAP Calibration Service, you do not need to order this option because Simco will send you a calibration certificate (see below for a description of the 21852 service).
Common Accessories
DCDC18R 12Vdc to 18Vdc Boost Regulator
The DCDC18R Boost Regulator accepts an 11 to 16 Vdc input and boosts it to 18 Vdc, which allows automotive supply voltages to recharge the CR3000's sealed rechargeable battery.
18359 CR3000 Insulated Terminal Cover
The CR3000's insulated aluminum thermocouple cover is intended to reduce thermal gradients across the analog inputs.
17394 USB to RS-232 Converter DB9 Male, 6ft
The 17394 interface cable provides a USB connector on one end and a 9-pin male RS-232 connector on the other end. The USB connector attaches to the USB port on a PC, and the RS-232 connector attaches to the RS-232 port on the CR3000.
SC110 Two RS-232 to Datalogger Control Port Cables, 2ft
The SC110 consists of two cables. One end of both cables provides stripped, tinned leads for attachment to the datalogger control ports. On the other end, one of the cables is fitted with a 9-pin male connector, and the other cable is fitted with a 9-pin female connector. By having two cables, connection to either an RS-232 DCE or DTE device is supported depending on the cable used.
9591 Wall Charger 18Vac 1.2A Output, 110Vac Input, 6ft Cable
Used with the -RC rechargeable base option, the 9591 recharges the sealed rechargeable battery via ac power. The transformer outputs 18 Vac @ 1.2 Amps and accepts 110 Vac.
14014 Wall Charger 18Vdc Output 90-264Vac 47-63Hz Input
The 14014 ac/dc universal power converter is generally used instead of the 9591 when local ac power is provided at voltages other than 110 Vac. The 14014 connects to ac power in the range of 90 to 264 Vac @ 47-63 Hz, then outputs a charge voltage of 18 Vdc for recharging the CR3000's sealed rechargeable battery.
Power Cable Options (hide details)
-NC -NC No Power Cable
The 14014 ac/dc universal power converter is generally used instead of the 9591 when local ac power is provided at voltages other than 110 Vac. The 14014 connects to ac power in the range of 90 to 264 Vac @ 47-63 Hz, then outputs a charge voltage of 18 Vdc for recharging the CR3000's sealed rechargeable battery.
-USC -USC US Cable
The 14014 ac/dc universal power converter is generally used instead of the 9591 when local ac power is provided at voltages other than 110 Vac. The 14014 connects to ac power in the range of 90 to 264 Vac @ 47-63 Hz, then outputs a charge voltage of 18 Vdc for recharging the CR3000's sealed rechargeable battery.
-EUC -EUC Europe Cable
The 14014 ac/dc universal power converter is generally used instead of the 9591 when local ac power is provided at voltages other than 110 Vac. The 14014 connects to ac power in the range of 90 to 264 Vac @ 47-63 Hz, then outputs a charge voltage of 18 Vdc for recharging the CR3000's sealed rechargeable battery.
-UKC -UKC UK/Ireland Cable
The 14014 ac/dc universal power converter is generally used instead of the 9591 when local ac power is provided at voltages other than 110 Vac. The 14014 connects to ac power in the range of 90 to 264 Vac @ 47-63 Hz, then outputs a charge voltage of 18 Vdc for recharging the CR3000's sealed rechargeable battery.
-AUC -AUC Australia/NZ Cable
The 14014 ac/dc universal power converter is generally used instead of the 9591 when local ac power is provided at voltages other than 110 Vac. The 14014 connects to ac power in the range of 90 to 264 Vac @ 47-63 Hz, then outputs a charge voltage of 18 Vdc for recharging the CR3000's sealed rechargeable battery.
-CNC -CNC China Cable
The 14014 ac/dc universal power converter is generally used instead of the 9591 when local ac power is provided at voltages other than 110 Vac. The 14014 connects to ac power in the range of 90 to 264 Vac @ 47-63 Hz, then outputs a charge voltage of 18 Vdc for recharging the CR3000's sealed rechargeable battery.
SP10 10W Solar Panel, 20ft Cable
The SP10 recharges the sealed rechargeable batteries using solar power. It provides a 10 W maximum peak power, 9 W guaranteed minimum power, 0.59 A current at peak, and 16.8 V voltage at peak.
SP20 20W Solar Panel, 15ft Cable
The SP20 recharges the sealed rechargeable batteries using solar power. It provides a 20 W maximum peak power, 18 W guaranteed minimum peak power, 1.19 A current at peak, and 16.8 V voltage at peak.
22110 Wall Charger 18Vac 1.2A Output, 110Vac Input, 6ft Cable for PWENC
The 22110 recharges the CR3000's sealed rechargeable battery via ac power. On one end, the 22110 has a plug that inserts into an ac wall socket and on the other end, it has a connector that attaches to the prewired enclosure. The 22110 outputs 18 Vac @ 1.2 Amps and accepts 110 Vac."
22111 Wall Charger 18Vdc Output 90-264Vac 47-63Hz Input for PWENC
This wall charger is generally used instead of the 22110 when local ac power is provided at voltages other than 110 Vac. On one end, the 22111 has a plug that inserts into an ac wall socket and on the other end, it has a connector that attaches to a prewired enclosure. This ac/dc transformer accepts inputs from 90 to 264 Vac @ 47 to 63 Hz, then outputs 18 Vdc."
Power Cable Options (hide details)
-NC -NC No Power Cable
This wall charger is generally used instead of the 22110 when local ac power is provided at voltages other than 110 Vac. On one end, the 22111 has a plug that inserts into an ac wall socket and on the other end, it has a connector that attaches to a prewired enclosure. This ac/dc transformer accepts inputs from 90 to 264 Vac @ 47 to 63 Hz, then outputs 18 Vdc."
-USC -USC US Cable
This wall charger is generally used instead of the 22110 when local ac power is provided at voltages other than 110 Vac. On one end, the 22111 has a plug that inserts into an ac wall socket and on the other end, it has a connector that attaches to a prewired enclosure. This ac/dc transformer accepts inputs from 90 to 264 Vac @ 47 to 63 Hz, then outputs 18 Vdc."
-EUC -EUC Europe Cable
This wall charger is generally used instead of the 22110 when local ac power is provided at voltages other than 110 Vac. On one end, the 22111 has a plug that inserts into an ac wall socket and on the other end, it has a connector that attaches to a prewired enclosure. This ac/dc transformer accepts inputs from 90 to 264 Vac @ 47 to 63 Hz, then outputs 18 Vdc."
-UKC -UKC UK/Ireland Cable
This wall charger is generally used instead of the 22110 when local ac power is provided at voltages other than 110 Vac. On one end, the 22111 has a plug that inserts into an ac wall socket and on the other end, it has a connector that attaches to a prewired enclosure. This ac/dc transformer accepts inputs from 90 to 264 Vac @ 47 to 63 Hz, then outputs 18 Vdc."
-AUC -AUC Australia/NZ Cable
This wall charger is generally used instead of the 22110 when local ac power is provided at voltages other than 110 Vac. On one end, the 22111 has a plug that inserts into an ac wall socket and on the other end, it has a connector that attaches to a prewired enclosure. This ac/dc transformer accepts inputs from 90 to 264 Vac @ 47 to 63 Hz, then outputs 18 Vdc."
-CNC -CNC China Cable
This wall charger is generally used instead of the 22110 when local ac power is provided at voltages other than 110 Vac. On one end, the 22111 has a plug that inserts into an ac wall socket and on the other end, it has a connector that attaches to a prewired enclosure. This ac/dc transformer accepts inputs from 90 to 264 Vac @ 47 to 63 Hz, then outputs 18 Vdc."
SP10-PW 10W Solar Panel, 20ft cable for PWENC
The cable on this version of the SP10 is fitted with a connector for attachment to a prewired enclosure. The SP10-PW provides a 10 W maximum peak power, 9 W guaranteed minimum power, 0.59 A current at peak, and 16.8 V voltage at peak."
SP20-PW 20W Solar Panel, 15ft Cable for PWENC
The cable on this version of the SP20 is fitted with a connector for attachment to a prewired enclosure. The SP20-PW provides a 20 W maximum peak power, 18 W guaranteed minimum peak power, 1.19 A current at peak, and 16.8 V voltage at peak."
21852 A2LA/NVLAP Datalogger Calibration Service w/Calibration Certificate
This service increases delivery time by approximately one week. The 21852 is offered for customers who require calibration validation from an accredited calibration laboratory. When the 21852 is ordered, Campbell Scientific calibrates the datalogger, and then sends the datalogger to Simco Electronics in Salt Lake City, Utah. After Simco receives the datalogger, they perform a calibration validation under the A2LA/NVLAP accreditation. Simco also provides a calibration certificate.
Replacement Parts
18531 CR3000 Operators Manual
The 18531 is offered for customers who want a paper CR3000 Operators Manual. This manual comes in a 3-ring binder. The price listed above is for paper manuals ordered without the datalogger.
905 Desiccant 1/2 Unit Bag
The 905 Single 0.5-Unit Desiccant Pack is used to desiccate the inside of the CR3000.
3768 2-Pin Screw Terminal Plug Connector .2 inch pitch Straight Wire Entry 12-24 AWG Green Marked G 12V
This green, plug-in power connector is shipped attached to the face of the CR3000 when the low-profile base is ordered. The 3768 provides screw terminals for connecting the 12 V and GND wires of the power supply. Please note that the power connector for the rechargeable base is the 3768 (see below).
7843 2-Pin Screw Terminal Plug Connector .15 inch pitch Straight Wire Entry 16-28 AWG w/Threaded Flange GRN
This 2-pin, detachable, power supply connector (green) is supplied with the rechargeable base of the CR3000. The 7843 can be purchased to replace a lost or damaged connector.
18173 Replacement CR3000 Excitation & Pulse Connector
This green terminal strip provides connectors for the excitation and pulse channels. The 18173 may be purchased to have a spare terminal strip or as a replacement item if the strip has been lost or damaged.
18172 Replacement CR3000 Analog Input 8-14 Connector
This green terminal strip provides connectors for the analog input channels labeled 8 through 14. The 18172 may be purchased to have a spare terminal strip or as a replacement item if the strip has been lost or damaged.
18171 Replacement CR3000 Analog Input 1-7 Connector
This green terminal strip provides connectors for the analog input channels labeled 1 through 7. The 18171 may be purchased to have a spare terminal strip or as a replacement item if the strip has been lost or damaged.
18170 Replacement CR3000 Control & Power Connector
This green terminal strip provides the connectors for the control and power channels. The 18170 may be purchased to have a spare terminal strip or as a replacement item if the strip has been lost or damaged.
17315 CR1000WP or CR3000 Peripheral Port Cover
The 17315 may be purchased to replace a lost or damaged cover. It sits on the peripheral port to protect it.
13519 3.6V 1.2Ah Lithium Battery 1/2AA
This 3.6 V lithium battery powers the clock and SRAM when the primary 12 Vdc power supply is not connected. The 13519 needs to be periodically replaced.
10645 Screw #10-32 x .312 Pan Slot Brass
This ground lug comes attached to the faceplate of the CR3000 next to the green power connector. The 10645 may be purchased to replace a lost or damaged ground lug.
18034 CR3000 Certificate of Calibration for S/N ???
The 18034 orders the two-page calibration certificate for your CR3000. If not specified, the CR3000 will be shipped without a calibration certificate.
8219 6V 7Ah Lead Acid Battery
The 8219 provides one of the 6-Vdc, 7-Ahr sealed rechargeable batteries used in the rechargeable base. To supply 12 Vdc, two 8219 batteries must be wired in series. Customers can generally replace these batteries.
Services
18542 CR3000 Retested to Extended Temp,-40 to +80C
Retesting is available only for individual units that have previously passed Extended Temperature Testing. Retesting also requires concurrent purchase of recalibration. An RMA (Returned Material Authorization) from Campbell Scientific is required.
18547 CR3000 Recalibration w/ Documentation,-25 to +50C
The 18547 requires an RMA (Returned Material Authorization) from Campbell Scientific. When ordered, the CR3000 is recalibrated to meet original specifications. Recalibration includes standard temperature testing (-25° to +50°C). Before and after calibration sheets are supplied with the datalogger. The calibration price assumes return of a fully functional datalogger; charges for all repairs will be added to the invoice.
18034 CR3000 Certificate of Calibration for S/N ???
The 18034 orders a two-page calibration certificate. If you are using the 21852 A2LA/NVLAP Calibration Service, you do not need to order this certificate because Simco will send you a calibration certificate.

Resources and Links

Ships With

(1) 10873 9-Pin Female to 9-pin Male serial cable, 6 ft

(1) 1113 Flat-bladed screwdriver

(1) 3315 Type T Thermocouple, 6 inches (18 cm)

(4) 505 Screws

(4) 6044 Grommets

(1) 8125 Flat screwdriver

Home \ Products \ Open... \ Open... \ Open... \ CR3000