Measurement and Control Products for WEATHER Measurement and Control Products for WATER Measurement and Control Products for ENERGY Measurement and Control Products for MACHINES Measurement and Control Products for STRUCTURES Measurement and Control Products for EARTH
Rugged Versatility
Multipurpose datalogger for monitoring and control
 
 
 
 
 
Image Gallery

Add to your Quote List

CR1000 Ordering Info
 
 
CR1000
Measurement and Control Datalogger
 
 
Temperature Ranges - show details
-ST -ST -25 to +50C
Every CR1000 is tested and guaranteed to perform within published specifications over the standard temperature range. Units are tested and shipped to standard operating range unless extended testing is specified.
-XT -XT -55 to +85C
For extended temperature range testing, analog accuracies are derated approximately two times over published specifications. Extended testing covers the -55° to +85°C range. Batteries are not temperature tested.
Warranty Lengths - show details
-SW -SW Standard 3yr Warranty
At the time of purchase, the CR1000 includes a standard warranty of 36 months. See our full warranty policy in the CR1000 manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our Extended Warranty adds 48 months to the standard 36 month warranty, bringing the total warranty period to 84 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
Calibration Certificate - show details
-NC -NC No Calibration Cert
The CR1000 is shipped without a calibration certificate.
-CC -CC Calibration Cert
When this option is chosen, a two-page calibration certificate is shipped with the datalogger. If you are using the 21852 A2LA/NVLAP Calibration Service, you do not need to order this option because Simco will send you a calibration certificate (see below for a description of the 21852 service).
Ships Within Restockable Warranty Compliance
28 Days Yes 3-year CE Compliance Image RoHS Compliance Image

Many of our products are built to order because they are customizable. Product build time can take up to the number of days indicated by the Ships Within value.

To estimate how long it will take to receive an order that contains multiple products, combine the largest Ships Within value with the transit time of the shipping method you select.

Some specialized products have large Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.

Ships With
  • (4) 505 - Screw #6-32 x .375 Pan Phillips
  • (1) 1113 - Flat-Bladed Screwdriver
  • (1) 8125 - Flat-Bladed Screwdriver, 2.5 mm Blade x 50 mm Shaft
  • (4) 6044 - Grommet for #6 or 8 Screw
  • (1) 10873 - Serial Data Cable, 9-Pin Female to 9-Pin Male
  • (1) Default datalogger program [#17598]
  • (1) 3315 - Type T Thermocouple
Common Accessories
 
 
SC32B
Optically Isolated RS-232 Interface
 
 
SC32B: Recommend 1 of 2 for Communication to AC Powered PC
CD100
Mountable Display with Keypad
 
 
CD100
A2LA/NVLAP Datalogger Calibration Service with Certificate
 
 
Will require 3 extra weeks for delivery.
CR1000KD
Keyboard/Display for the CR1000, CR800, or CR6
 
 
The CR1000KD is a portable keyboard display for viewing and entering datalogger data. One CR1000KD may be carried from station to station in a CR1000 network. Users can customize menus and displays, simplifying routine operations.
SC110
Two Cables, RS-232 to Datalogger Control Port
 
 
SC110
17324
CR1000WP Insulated Terminal Cover
 
 
17394
Converter, USB to DB9 Male RS-232
 
 
For use with SC32B
SC-CPI
Datalogger-to-CPI Interface
 
 
Will need if using CDMs
Temperature Ranges - show details
-ST -ST -25 to +50C
Every SC-CPI is tested and guaranteed to perform within published specifications over the standard temperature range.Units are tested and shipped to standard operating range unless extended testing is specified.
-XT -XT -55 to +85C
Extended temperature testing over the -55° to +85°C range is also available. Individual units are subjected to performance tests at these extremes in a test chamber. Units that pass the tests are certified as extended temperature units.
Warranty Lengths - show details
-SW -SW Standard 1yr Warranty
At the time of purchase, the SC-CPI includes a standard warranty of 12 months. See our full warranty policy in the SC-CP manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our extended warranty adds 48 months to the standard 12 month warranty, bringing the total warranty period to 60 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
SC-USB
Optically Isolated USB Interface
 
 
SC-USB: Recommend 1 of 2 for Communication to AC Powered PC
Other Accessories
 
 
SC32B
Optically Isolated RS-232 Interface
 
 
This optically isolated interface is for connecting an AC-powered PC with the CR1000. The SC32B includes a cable that attaches to the datalogger's CS I/O port and another cable that attaches to the PC's 9-pin serial port. Customers who want to use the PC's USB port instead of the its 9-pin serial port should purchase the SC-USB interface (see below).
CD100
Mountable Display with Keypad
 
 
The CD100 can be mounted in an enclosure lid allowing the user to enter and view data without opening the enclosure. It has a vacuum flourescent display for responsive use through a very wide operating temperature range. Users can customize menus and displays, simplifying routine operations.
A2LA/NVLAP Datalogger Calibration Service with Certificate
 
 
This service increases delivery time by approximately one week. The 21852 is offered for customers who require calibration validation from an accredited calibration laboratory. When the 21852 is ordered, Campbell Scientific calibrates the datalogger, and then sends the datalogger to Simco Electronics in Salt Lake City, Utah. After Simco receives the datalogger, they perform a calibration validation under the A2LA/NVLAP accreditation. Simco also provides a calibration certificate.
CR1000KD
Keyboard/Display for the CR1000, CR800, or CR6
 
 
The CR1000KD is a portable keyboard display for viewing and entering datalogger data. One CR1000KD may be carried from station to station in a CR1000 network. Users can customize menus and displays, simplifying routine operations.
SC110
Two Cables, RS-232 to Datalogger Control Port
 
 
The SC110 consists of two cables, each 2 ft (0.6 m) in length. One cable consists of a 9-pin male connector on one end with stripped and tinned leads on the other for connection to CR1000 Control Ports. The other cable is identical except that a 9-pin female connector replaces the male connector. By having two cables, connection of either an RS-232 DCE or DTE device is supported, depending on the cable used.
17324
CR1000WP Insulated Terminal Cover
 
 
The 17324 provides an insulated aluminum thermocouple cover that helps reduce thermal gradients across the analog inputs.
17394
Converter, USB to DB9 Male RS-232
 
 
The 17394 provides a USB connector on one end and a 9-pin male RS-232 connector on the other end. The USB connector attaches to the USB port on a PC, and the RS-232 connector attaches to the RS-232 port on the CR1000.
SC-CPI
Datalogger-to-CPI Interface
 
 
The SC-CPI allows the CR1000 to communicate with a CDM.
Temperature Ranges - show details
-ST -ST -25 to +50C
Every SC-CPI is tested and guaranteed to perform within published specifications over the standard temperature range.Units are tested and shipped to standard operating range unless extended testing is specified.
-XT -XT -55 to +85C
Extended temperature testing over the -55° to +85°C range is also available. Individual units are subjected to performance tests at these extremes in a test chamber. Units that pass the tests are certified as extended temperature units.
Warranty Lengths - show details
-SW -SW Standard 1yr Warranty
At the time of purchase, the SC-CPI includes a standard warranty of 12 months. See our full warranty policy in the SC-CP manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our extended warranty adds 48 months to the standard 12 month warranty, bringing the total warranty period to 60 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
SC-USB
Optically Isolated USB Interface
 
 
The SC-USB Optically Isolated Interface provides similar functionality as the SC32B, except it connects with the PC's USB port instead of the PC's 9-pin serial port.
Replacement Parts
 
 
6554
Desiccant 1/6-Unit Bag
 
 
This desiccant pack fits inside of the CR1000 module. The 6554 is generally replaced when the internal lithium battery is replaced.
CR1000 Operator's Manual
 
 
The 17746 is offered for customers who want a paper CR1000 Operators Manual. This manual comes in a 3-ring binder. The price listed above is for paper manuals ordered without the datalogger. Paper manuals ordered on the same purchase order as the datalogger are available at no extra charge. However, the customer must indicate that they want a paper manual. Otherwise, they will receive a ResourceDVD containing a PDF version of the manual.
Screw #10-32 x .312 Pan Slot, Brass
 
 
The 10645 is the screw used in the ground lug.
Peripheral Port Cover for the CR1000 or CR3000
 
 
The 17315 protects the peripheral port and may be purchased to replace a lost or damaged cover.
Flat-Bladed Screwdriver
 
 
The 1113 Flat-bladed screwdriver is used to attach sensor leads to the wiring panel's screw terminals.
3768
2-Pin Screw Terminal Plug Connector
 
 
The 3768 is shipped attached to the CR1000. This green, plug-in power connector provides screw terminals for connecting the 12 V and GND wires of the datalogger's power supply. The 3768 may be purchased to replace a lost or damaged power connector.
13519
Replacement Lithium Battery
 
 
The 13519 fits inside of the CR1000 module. This lithium battery powers the clock and SRAM when the primary 12 Vdc power supply is not connected. The 13519 can be replaced by the user; the process is illustrated in the CR1000 Operator's Manual.
Wiring Panel for CR1000
 
 
The CR1000WP provides a black, anodized aluminum wiring panel with "CR1000WP" labeled in white. It may be purchased to replace a lost or damaged wiring panel. A complete CR1000 datalogger requires the CR1000WP to be connected to a CR1000M module.
Warranty Lengths - show details
-SW -SW Standard 3yr Warranty
At the time of purchase, the CR1000WP includes a standard warranty of 36 months. See our full warranty policy in the CR1000 manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our Extended Warranty adds 48 months to the standard 36 month warranty, bringing the total warranty period to 84 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
Services
 
 
Onsite Training Class, 4 Days, CR1000, by 1 Application Engineer
 
 
If you have a large group of individuals who require standard or custom training, it may be cost-effective for us to come to you. This class includes 4 days of training on the CR1000 and LoggerNet. One Applications Engineer conducts the training (5 people maximum). Our travel expenses within the continental United States are included, as are use of dataloggers, computers, software, sensors, and instructional materials. Our training materials are shipped in cases that contain 3 training set-ups per case; we have four cases available for training.
CR1000 Retested to Extended Temperature (-55° to +85°C)
 
 
Retesting is available only for individual units that have previously passed Extended Temperature Testing. Retesting also requires concurrent purchase of recalibration. An RMA (Returned Material Authorization) from Campbell Scientific is required.
CR1000 Recalibration with Documentation (-25° to +50°C)
 
 
The 17749 requires an RMA (Returned Material Authorization) from Campbell Scientific. When ordered, we recalibrate the CR1000 to meet original specifications. Recalibration includes standard temperature testing (-25° to +50°C). Before and after calibration sheets are supplied with the CR1000.
Training Class at Campbell Scientific, 4 Days, CR1000/LoggerNet, for 1 Person
 
 
We offer training courses at our factory in Logan, Utah. Price includes 4 days of instruction on the CR1000 Datalogger and LoggerNet software, and allows the use of training computers, dataloggers, and facilities. Travel and accommodations are NOT included. Lunch will be provided by CSI on each day of class.
Onsite Training Class, 4 Days, CR1000, by 2 Application Engineers
 
 
This class includes 4 days of training on the CR1000 and LoggerNet. Two Applications Engineers conduct the training (11 people maximum). Our travel expenses within the continental United States are included, as are use of dataloggers, computers, software, sensors, and instructional materials. Our training materials are shipped in cases that contain 3 training set-ups per case; we have four cases available for training.
CR1000 Certificate of Calibration
 
 
The 16131 orders the two-page calibration certificate. If you are using the 21852 A2LA/NVLAP Calibration Service, you do not need to order this because Simco will send you a calibration certificate (see above for a description of the 21852 service).
CR1000 Training Materials
 
 

Resources and Links

Shipping Weights & Dims

Single Box Shipping Weight:
     9.0 lb
     4.1 kg

Single Box Shipping Dimensions:
     12" x 12" x 8"
     30.5 x 30.5 x 20.3 cm