This product is no longer available and has been replaced by: CR1000. Some accessories, replacement parts, or services may still be available.
Sections:
Replacement Parts,
Services
This product is currently unavailable for orders.
| Replacement Parts | |
| 17161 | CR10 Operator's Manual |
|
An extra copy of the CR10 Operator's Manual may be purchased.
|
|
| CR10TCR | Thermocouple Reference for CR10 Wiring Panel |
|
The CR10TCR is an external thermistor that provides a reference temperature for thermocouple measurements. The CR10TCR is only compatible with the black CR10 wiring panel that was shipped before 21 May '97. The silver CR10 wiring panel requires the 10TCRT; the black CR10X Wiring Panel (also known as the CR10XWP) requires the CR10XTCR.
|
|
| 10TCRT | Thermistor Reference for CR10 |
|
The 10TCRT is an external thermistor that provides a reference temperature for thermocouple measurements. The 10TCRT is only compatible with the silver CR10 wiring panel. The leads are too short for either the black CR10 wiring panel or the black CR10X wiring panel.
|
|
| 17174 | CR10 Service Manual Requires Non-Disclosure Agreement |
|
The CR10 Service Manual includes assembly drawings and schematics only. It does not contain detailed procedural or repair information. A signed non-disclosure agreement is required prior to shipping.
|
|
| 5478 | CR10 Prompt Sheet |
|
The 5478 provides an additional copy of the CR10 prompt sheet, originally found in CR10 manuals. The Prompt Sheet covers the standard OS10 operating system only. Alternatively, a PDF of the CR10 Prompt Sheet is available from our Web site.
|
|
| CR10XWP | Wiring Panel |
|
The CR10XWP is a black, anodized aluminum wiring panel with "CR10X" labeled in white. It includes a switched 12-V terminal, redistributed analog grounds (dispersed among analog channels rather than grouped), unpluggable terminal block for 12 V connections, gas-tube spark gaps, and 12 V supply on pin 8 to power our COM-series phone modems and other peripherals. This configuration no longer supports cassette tapes.
|
|
| 16539 | CR10K 4K Program Memory Modification for units w/ SrlNo greater than 19271 |
|
The 16539 is a program memory modification for the CR10 dataloggers. It can be done at the factory (request RMA) or by the customer. The 16539 includes the LS17424 PROM and a manual. A jumper setting must also be changed. The 16539 does not provide recalibration, checkout, or temperature testing.
|
|
| LS5954 | CR10 OS10.1 Library Special PROM |
|
The LS5954 contains specialized instructions and features that are individually incorporated in the PROM by a Campbell Scientific applications engineer. For each specialized instruction added to the PROM, a standard instruction typically needs to be removed. The LS5954 can be installed in the CR10 at the factory or by the user. For factory installation, specify at time of order or request an RMA from Campbell Scientific.
|
|
| LS6159 | CR10 OS10.1 4K Library Special PROM |
|
The LS6159 contains specialized instructions and features that are individually incorporated in the PROM by a Campbell Scientific applications engineer. For each specialized instruction added to the PROM, a standard instruction typically needs to be removed. The PROM can be installed in the CR10 at the factory or by the user. For factory installation, specify at time of order or request an RMA from Campbell Scientific.
|
|
| LS7788 | CR10 UDG01 PROM |
|
This PROM contains standard instructions plus UDG01 snow depth sensor measurement and SDI-12 communication protocol (for some "smart" sensors). The LS7788 can be installed by the customer or at our factory; if factory-installed, an RMA (Returned Material Authorization) is required. List price is for the PROM only.
|
|
| LS14150 | CR10 SAT HDR GOES Library Special PROM |
|
This PROM updates the firmware in our CR10 to be SAT HDR GOES compatible. The LS14150 is sent to the user for installation.
|
|
| LS6545 | CR10 Dynagage PROM |
|
This PROM contains standard instructions plus the Dynagage processing Instruction. The LS6545 was previously known as the "-D" option.
|
|
| LS7306 | CR10 DECAGON CX2R3 PROM |
|
This PROM contains the standard instructions plus Dynagage processing. The LS7306 can be installed by the customer or at our factory; if factory installed, an RMA (Returned Material Authorization) is required. The price listed under Ordering Info is for the PROM only.
|
|
| LS6674 | CR10 USGS 4K Program Memory PROM |
|
The CR10 USGS 4K Program Memory PROM can be installed in the CR10 at the factory or by the user. For factory installation, specify at time of order or request an RMA from Campbell Scientific.
|
|
| LS6675 | CR10 Hughes PROM |
|
The CR10 Hughes PROM can be installed in the CR10 at the factory or by the user. For factory installation, specify at time of order or request an RMA from Campbell Scientific.
|
|
| LS7304 | CR10 Climatronics P96 CHKSUM PROM |
|
This PROM contains standard instructions plus P96 Check Sum. The LS7304 can be installed by the customer or at our factory; if factory installed, an RMA (Returned Material Authorization) is required. The price listed under Ordering Info is for the PROM only.
|
|
| LS7305 | CR10 Climatronics P96 CHKSUM EEPROM |
|
This CR10 PROM contains standard instructions plus P96 Check Sum and EEPROM program. The LS7305 can be installed by the customer or at our factory; if factory-installed, an RMA (Returned Material Authorization) is required. List price is for the PROM only.
|
|
| LS8131 | CR10 Telonics GOES PROM |
|
The LS8131 PROM Set provides the capability to interface a model CR10 datalogger (not CR10X) to a Telonics GOES transmitter. These PROMs are typically installed by the user. If you prefer to have the PROMs installed at the factory (incurs additional cost), request an RMA from Campbell Scientific.
|
|
| LS5361 | CR10 Rain Bird PROM |
|
The LS5361 PROM is for Rain Bird use only.
|
|
| LS5696 | CR10 COMAX PROM |
|
The LS5696 is a specialized CR10 PROM developed for the Cotton Growers.
|
|
| LS5820 | CR10 012 Weather Station PROM |
|
The LS5820 PROM is used in model 012 Weather Stations equipped with CR10 dataloggers. The 012 was used mostly in commercial agriculture and bore many similarities to the ET107 Weather Station.
|
|
| LS6720 | CR10 TDR PROM |
|
This PROM contains standard instructions plus instructions for measuring a Tektronix-based TDR system. The LS6720 can be installed in the CR10 at the factory or by the user. For factory installation, specify at time of order or request an RMA from Campbell Scientific.
|
|
| Services | |
| 15842 | CR10 Retested to Extended Temp (-55 to +85C) |
|
The 15842 is available only for CR10 dataloggers that have previously passed Extended Temperature Testing. Retesting requires concurrent purchase of the 16540 Recalibration and an RMA (Returned Material Authorization) from Campbell Scientific.
|
|
| 16129 | CR10 Tested to Extended Temp (-55 to +85C) |
|
The 16129 tests the CR10 to the range of -55° to +85°C. For this temperature range, analog accuracies are derated approximately two times over published specifications. Extended Temperature Testing is typically specified at the time of datalogger purchase and is first performed before the datalogger ever leaves the factory. However, if application requirements change, individual dataloggers can also be returned to Campbell Scientific on an RMA to determine if they can pass Extended Temperature Testing. Extended temperature testing of a previously purchased unit also requires purchase of concurrent recalibration.
|
|
| 16540 | CR10 Recalibration w/ Documentation,-25 to +50C |
|
The 16540 recalibrates a CR10 datalogger to meet original specifications. Before and after calibration sheets are supplied with the datalogger. Recalibration includes standard temperature testing (-25° to +50°C). If extended temperature testing is desired, the 15842 must also be purchased. An RMA (Returned Material Authorization) from Campbell Scientific is required.
|
|
| 16538 | CR10K 4K Program Memory Modification for units w/ SrlNo less than 19272 |
|
The 16538 is a hardware modification that expands the CR10's program memory from 1978 to 4023 bytes. Available data storage is reduced by approximately 2 kbytes. The CR10 must be returned to Campbell Scientific. Fee also includes a new PROM [LS17424], recalibration, full checkout, temperature testing, and manual.
|
|
| LS6813 | CR10 64Hz Pulse Count Reset PROM |
|
The LS6813 64 Hz Pulse Count Reset allows pulse counter to be read up to 64 times a second. It increases maximum frequency to 16,320 Hz (high frequency pulse, 8-bit counter). This is available for OS10-0.1 instruction set only. Fee includes recalibration, Standard Checkout with Temperature Testing, and manual.
|
|
Resources and Links
Related Documents
Related Products
Shipping Weights & Dims
Shipping weight:
8 lbs
3.63 kg