CMP10
CMP10
OrderableISO Class A Pyranometer
Overview
The CMP10, manufactured by Kipp & Zonen, is an ISO Class A (secondary standard) pyranometer that monitors solar radiation for the full solar spectrum range. It connects directly to a Campbell Scientific data logger and is well-suited for meteorological networks and solar-energy research and development.
Technical Description
The CMP10 measures solar radiation with a high-quality blackened thermopile protected by two glass domes. Its flat spectral sensitivity, from 285 to 2800 nm, makes it ideal for applications in natural sunlight, under plant canopies, in greenhouses or buildings, and inverted to measure reflected solar radiation.
An internal drying cartridge prevents dew from forming on the inner sides of the CMP10's domes. Campbell Scientific also offers the CVF4 heater/ventilator that keeps its domes free from ice and dew.
The CMP10 includes a white snap-on sun shield that reduces the sensor's temperature. A bubble level and adjusting leveling screws enable the sensor to be leveled without using a leveling base.
The CMP10 produces a millivolt signal that is measured directly by a Campbell Scientific data logger.
Benefits
- Detector design and faster response make it a step above the CMP6
- Compatible with most Campbell Scientific data loggers
- Integrated bubble level is visible without removing sun shield
- Internal drying cartridge prevents dew from forming on the inner sides of the domes
- Compatible with the CVF4 heater/ventilator that keeps the domes free from ice and dew
- Measures reflected solar radiation when inverted
- Provides measurements in direct sunlight, under plant canopies, when the sky is cloudy, and in artificial light
Specifications
- Sensor
- High-quality blackened thermopile protected by two glass domes
- Measurement Description
- Monitors solar radiation for the full solar spectrum range
- ISO Classification
- Class A (secondary standard)
- Spectral Range
- 285 to 2800 nm
- Sensitivity
- 7 to 14 µV/W/m2
- Temperature Dependence of Sensitivity
- < 1%
(-10° to +40°C)
- Response Time
- < 5 s
(95% of final value)
- Zero Offset Due to Thermal Radiation
- < 7 W/m2
(200 W/m2)
- Non-Stability
- < 0.5%
(change/year)
- Non-Linearity
- < 0.2%
(0 to 1000 W/m2)
- Directional Error
- < 10 W/m2
(up to 80° with 1000 W/m2 beam)
- Tilt Error
- < 0.2%
- Level Accuracy
- 0.1°
- Impedance
- 10 to 100 Ω
- Operating Temperature Range
- -40° to +80°C
- Typical Signal Output
- 0 to 15 mV
(for atmospheric applications)
- Maximum Irradiance
- 4000 W/m2
- Expected Daily Uncertainty
- < 2%
- Dome Diameter
- 5 cm
(2 in.)
- Width
- 15 cm
(5.9 in.) with shield
- Height
- 9.25 cm
(3.64 in.)
- Weight
- 0.9 kg
(2 lb) with 10.1 m (33 ft) cable
Accessories
(6)Related Resources
Case Studies
Documents
- Technical Paper
From Sensor to Decision: Evapotranspiration
August 2021
View Document - Brochure
CMP10 ISO Class A Pyranometer
March 2026
View Document - Manual
Kipp and Zonen CMP-Series Pyranometers
View Document - Brochure
Kipp and Zonen CMP-Series Pyranometers
View Document
Showing 4 of 7 results
See all Documents