Measurement and Control Products for WEATHER Measurement and Control Products for WATER Measurement and Control Products for ENERGY Measurement and Control Products for MACHINES Measurement and Control Products for STRUCTURES Measurement and Control Products for EARTH
Greatly Increases Sensor Capacity
Connects many sensors to single datalogger
 
 
 
 
 
Image Gallery
AM16/32B Pricing Details
Educational Discounts: Yes    Quantity Discounts: Yes    Restockable: Yes    Warranty: 1 year   
Model Description
AM16/32B 16 or 32 Channel Relay Multiplexer
Temperature Ranges (hide details)
-ST -ST Tested -25 to +50C
Standard Temperature Testing range is -25° to +50°C. Individual units are warranted to perform within published specifications over this range, which is included with product purchase.
-XT -XT Tested -55 to +85C
Extended Temperature Testing over the -55° to +85°C range is also available. Individual units are subjected to performance tests at these extremes in a test chamber. Units that pass the tests are certified as extended temperature units.
Warranty Lengths (hide details)
-SW -SW Standard 1yr Warranty
At the time of purchase, the AM16/32B includes a standard warranty of 12 months. See our full warranty policy in the AM16/32B manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our Extended Warranty adds 48 months to the standard 12-month warranty, bringing the total warranty period to 60 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
Common Accessories
CABLE4CBL-L 4-Conductor 22AWG Cable w/Drain
This 22-AWG, four-conductor cable has a Santoprene® jacket and an aluminum mylar shield. The CABLE4CBL-L is the preferred cable for supplying power and control signals from the datalogger to the AM16/32B. When the AM16/32B is used in the 4 x 16 mode, another CABLE4CBL-L can connect the measurement/excitation channels of the datalogger with the COM terminals of the multiplexer. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
CABLE4CBL-L Options (hide details)
-L ft per cable
This 22-AWG, four-conductor cable has a Santoprene® jacket and an aluminum mylar shield. The CABLE4CBL-L is the preferred cable for supplying power and control signals from the datalogger to the AM16/32B. When the AM16/32B is used in the 4 x 16 mode, another CABLE4CBL-L can connect the measurement/excitation channels of the datalogger with the COM terminals of the multiplexer. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
Cable Termination Options (hide details)
-PT -PT w/Tinned Wires
This 22-AWG, four-conductor cable has a Santoprene® jacket and an aluminum mylar shield. The CABLE4CBL-L is the preferred cable for supplying power and control signals from the datalogger to the AM16/32B. When the AM16/32B is used in the 4 x 16 mode, another CABLE4CBL-L can connect the measurement/excitation channels of the datalogger with the COM terminals of the multiplexer. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
-PW -PW w/Pre-Wire Connector
This 22-AWG, four-conductor cable has a Santoprene® jacket and an aluminum mylar shield. The CABLE4CBL-L is the preferred cable for supplying power and control signals from the datalogger to the AM16/32B. When the AM16/32B is used in the 4 x 16 mode, another CABLE4CBL-L can connect the measurement/excitation channels of the datalogger with the COM terminals of the multiplexer. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
CABLE3CBL-L 3-Conductor 22AWG Cable w/Drain
This 22-AWG, three-conductor cable has a Santoprene® jacket and an aluminum mylar shield. When used in a 2 x 32 mode, the CABLE3CBL-L cable is recommended for connecting the measurement/excitation channels of the datalogger with the COM terminals of the multiplexer. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
CABLE3CBL-L Options (hide details)
-L ft per cable
This 22-AWG, three-conductor cable has a Santoprene® jacket and an aluminum mylar shield. When used in a 2 x 32 mode, the CABLE3CBL-L cable is recommended for connecting the measurement/excitation channels of the datalogger with the COM terminals of the multiplexer. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
Cable Termination Options (hide details)
-PT -PT w/Tinned Wires
This 22-AWG, three-conductor cable has a Santoprene® jacket and an aluminum mylar shield. When used in a 2 x 32 mode, the CABLE3CBL-L cable is recommended for connecting the measurement/excitation channels of the datalogger with the COM terminals of the multiplexer. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
-PW -PW w/Pre-Wire Connector
This 22-AWG, three-conductor cable has a Santoprene® jacket and an aluminum mylar shield. When used in a 2 x 32 mode, the CABLE3CBL-L cable is recommended for connecting the measurement/excitation channels of the datalogger with the COM terminals of the multiplexer. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
CABLE5CBL-L 5-Conductor 22AWG Cable w/Drain
This 24-AWG, five-conductor cable has a Santoprene® jacket and an aluminum mylar shield. For the 4 x 16 mode, the CABLE5CBL-L is recommended for connecting the COM terminals when it is desirable to connect both shields. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
CABLE5CBL-L Options (hide details)
-L ft per cable
This 24-AWG, five-conductor cable has a Santoprene® jacket and an aluminum mylar shield. For the 4 x 16 mode, the CABLE5CBL-L is recommended for connecting the COM terminals when it is desirable to connect both shields. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
Cable Termination Options (hide details)
-PT -PT w/Tinned Wires
This 24-AWG, five-conductor cable has a Santoprene® jacket and an aluminum mylar shield. For the 4 x 16 mode, the CABLE5CBL-L is recommended for connecting the COM terminals when it is desirable to connect both shields. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
-PW -PW w/Pre-Wire Connector
This 24-AWG, five-conductor cable has a Santoprene® jacket and an aluminum mylar shield. For the 4 x 16 mode, the CABLE5CBL-L is recommended for connecting the COM terminals when it is desirable to connect both shields. A 2-foot length should be sufficient if the datalogger and AM16/32B are housed in an ENC16/18 enclosure.
Replacement Parts
19237 AM16/32A Replacement Cover
This terminal cover helps reduce thermal gradients across the input terminals and protects the input connections from unintended jostling.