Multiplexers
The 4WFBS350 is compatible with our multiplexers.
Datalogger Considerations
The 4WFBS350 uses one differential analog input; an adjacent analog ground channel accepts the "ground prong" of the 4WFBS350. Not all datalogger terminal strips have this sequence on all channels, so please check your datalogger's wiring panel to confirm channel assignments, especially if you plan to use multiple Terminal Input Modules.
The lead wire that emanates from the head of the 4WFBS350 connects to a datalogger excitation channel.
Please note that if a CR10X will be used to measure thermocouples in the same application, newer CR10X Wiring Panels and the CR10XTCR Reference Thermistor (with its accompanying Thermocouple Cover) are deep enough to cover the datalogger input channels with a Terminal Input Module attached; older CR10TCRs are not deep enough.
Programming
The 4WFBS350 is measured with the BrFull Instruction in CRBasic, and with Instruction 6 (Full Bridge) in Edlog.
Compatible Contemporary Dataloggers
| CR200(X) Series | CR800/CR850 | CR1000 | CR3000 | CR5000 | CR7X | CR9000X |
![]() |
![]() |
![]() |
![]() |
* | ** |
Compatible Retired Datalogger
| CR500 | CR510 | CR10 | CR10X | 21X | CR23X | CR9000 |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
** |
Datalogger Notes:
*As shipped, the prongs on the 4WFBS350 are too short to fit the CR7. If you're determined to use the 4WFBS350 with a CR7, you can solder wire to the prongs, thereby extending their length.
**Compatible CR9000(X) modules are the CR9050 and the CR9052; the CR9051 is partially compatible.
Resources and Links
Shipping Weights & Dims
2.0 lbs
907 g
Single Box Shipping Dimensions:
12" x 12" x 4"
30.5 x 30.5 x 10.3 cm