Compatible with most Campbell Scientific dataloggers
Mounting
The Wind Monitors can be attached to a CM202, CM204, or CM206 crossarm via a 17953 NU-RAIL fitting or CM220 Right Angle Mounting Bracket. Alternatively, the Wind Monitors can be attached to the top of our stainless-steel tripods via the CM216 Sensor Mounting Kit.
Datalogger Considerations
The 05305's propeller uses one pulse count channel on the datalogger. Its wind vane requires one single-ended channel and access to an excitation channel (the excitation channel can be shared with other high impedance sensors).
Programming
The 05305's propeller is measured by the PulseCount Instruction in CRBasic and by Instruction 3 (Pulse Count) in Edlog. The wind vane is measured by the BrHalf Instruction in CRBasic and by Instruction 4 (Excite-Delay-SE) in Edlog. The measurements are typically processed for output with the Wind Vector instruction (not present in the CR500 or CR9000 but is present in the CR9000X).
Compatible Contemporary Dataloggers
| CR200(X) Series | CR800/CR850 | CR1000 | CR3000 | CR5000 | CR7X | CR9000X |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Compatible Retired Dataloggers
| CR500 | CR510 | CR10 | CR10X | 21X | CR23X | CR9000 |
![]() |
![]() |
![]() |
![]() |
![]() |
Resources and Links
Related Products
Ships With
(1) Allen wrench from original mfg
(1) Bearing spacer from original mfg
(1) Calibration Sheet
(1) 3659 Mounting pipe
Shipping Weights & Dims
5.0 lb plus 0.3 lb per
10' of cable
2.3 kg plus 0.14 kg
per 3.05 m of cable
Single Box Shipping Dimensions:
36" x 20" x 15"
91.4 x 50.8 x 38.1 cm