Measurement and Control Products for WEATHER Measurement and Control Products for WATER Measurement and Control Products for ENERGY Measurement and Control Products for MACHINES Measurement and Control Products for STRUCTURES Measurement and Control Products for EARTH
Reliable, Accurate Wind Measurements
Compatible with most Campbell Scientific dataloggers
05106-L Pricing Details
Educational Discounts: Yes    Quantity Discounts: Yes    Restockable: Yes    Warranty: 1 year   
Model Description
05106-L RM Young Wind Monitor Marine Version
05106-L Options (hide details)
-L ft cable per sensor
Custom lead lengths are available for up to 1000 feet. Campbell Scientific recommends:
  • 11 ft—sensor mounted atop a CM6 via a CM202
  • 14 ft—sensor mounted atop a CM106, CM10, CM110, or UT10 via a CM202
  • 19 ft—sensor mounted atop a CM115 via a CM202
  • 24 ft—sensor mounted atop a UT20 via a CM202
  • 37 ft—sensor mounted atop a UT30 via a CM202
Cable Termination Options (hide details)
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a prewired enclosure.
-CWS -CWS w/CWS900 Connector
With the -CWS option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows this sensor to be used in a wireless sensor network.
Common Accessories
17953 1 x 1 inch NURAIL Crossover Fitting
The 17953 NU-RAIL® Crossover Fitting is used to mount this sensor to a crossarm or a user-supplied 1" IPS pipe. This usage is equivalent to the functionality provided by the CM220 Right Angle Mounting Bracket.
CM220 Right Angle Mounting Kit
The CM220 Right Angle Mounting Bracket is used to mount this sensor to a crossarm or a user-supplied 1" IPS pipe.
CM216 Sensor Mounting Kit for Top of SS Tripod Mast for CM110-series
The CM216 Sensor Mount provides a connection point for this sensor to be attached to the top of a stainless steel CM110, CM115, or CM120 Tripod.
Other Accessories
-SW -SW Standard 1yr Warranty
The LLAC4 can be used to increase the number of sensors measured by one datalogger.
-XW -XW 4yr Warr Extension
The LLAC4 can be used to increase the number of sensors measured by one datalogger.
LLAC4 4-Channel Low-Level AC Conversion Module
The LLAC4 can be used to increase the number of sensors measured by one datalogger.
Warranty Lengths (hide details)
Replacement Parts
05106CBL-L 05106-L Replacement Cable
The 05106CBL-L Replacement Cable has a connector on one end and pigtails on the other end. The pigtails connect to the datalogger's input terminals. The connector connects to the 3-foot (1-m) cable that is attached to the Wind Monitor. The 05106CBL is typically ordered with 7, 10, 16, 21, or 31 ft length. These lengths provide a total cable length of 10, 13, 19, 24, or 34 ft.

The 05106CBL-L was previously ordered at the 17145.
05106CBL-L Options (hide details)
-L ft per sensor cable
The 05106CBL-L Replacement Cable has a connector on one end and pigtails on the other end. The pigtails connect to the datalogger's input terminals. The connector connects to the 3-foot (1-m) cable that is attached to the Wind Monitor. The 05106CBL is typically ordered with 7, 10, 16, 21, or 31 ft length. These lengths provide a total cable length of 10, 13, 19, 24, or 34 ft.

The 05106CBL-L was previously ordered at the 17145.
Cable Termination Options (hide details)
-PT -PT w/Tinned Wires
The 05106CBL-L Replacement Cable has a connector on one end and pigtails on the other end. The pigtails connect to the datalogger's input terminals. The connector connects to the 3-foot (1-m) cable that is attached to the Wind Monitor. The 05106CBL is typically ordered with 7, 10, 16, 21, or 31 ft length. These lengths provide a total cable length of 10, 13, 19, 24, or 34 ft.

The 05106CBL-L was previously ordered at the 17145.
-PW -PW w/Pre-Wire Connector
The 05106CBL-L Replacement Cable has a connector on one end and pigtails on the other end. The pigtails connect to the datalogger's input terminals. The connector connects to the 3-foot (1-m) cable that is attached to the Wind Monitor. The 05106CBL is typically ordered with 7, 10, 16, 21, or 31 ft length. These lengths provide a total cable length of 10, 13, 19, 24, or 34 ft.

The 05106CBL-L was previously ordered at the 17145.
-CWS -CWS w/CWS900 Connector
The 05106CBL-L Replacement Cable has a connector on one end and pigtails on the other end. The pigtails connect to the datalogger's input terminals. The connector connects to the 3-foot (1-m) cable that is attached to the Wind Monitor. The 05106CBL is typically ordered with 7, 10, 16, 21, or 31 ft length. These lengths provide a total cable length of 10, 13, 19, 24, or 34 ft.

The 05106CBL-L was previously ordered at the 17145.
13895 Replacement Vertical Shaft Bearing for 05103 or 05106 (two required)
The 13895 bearings allow the wind vane to turn about the axis of the mounting shaft. These bearings are located within the shaft assembly and replacement at the factory is strongly recommended; please request an RMA.
13894 Replacement Propeller Shaft Bearing for 05103 or 05106 (two required)
The 13894 bearings are located in the propeller housing. The bearings can be replaced by mechanically-adept users—especially if they are familiar with replacing bearings in other mechanical systems. Otherwise, replacement at the factory is recommended (requires an RMA).

Resources and Links

Ships With

(1) Allen wrench from original mfg

(1) Bearing spacer from original mfg

(1) Calibration Sheet

(1) 3659 Aluminum pipe

Shipping Weights & Dims

Single Box Shipping Weight:
     5.0 lb plus 0.3 lb per
        10' of cable
     2.3 kg plus 0.14 kg per
        3.05 m of cable

Single Box Shipping Dimensions:
     29" x 17" x 9"
     73.7 x 43.2 x 22.9 cm
Home \ Products \ Components \ Sensors \ Wind... \ 05106-L