Measurement and Control Products for WEATHER Measurement and Control Products for WATER Measurement and Control Products for ENERGY Measurement and Control Products for MACHINES Measurement and Control Products for STRUCTURES Measurement and Control Products for EARTH
Reliable, Accurate Wind Direction
Compatible with most Campbell Scientific dataloggers
 
 
 
 
 
Image Gallery

Mounting

The 024A can be attached to a CM202, CM204, or CM206 crossarm via a 17953 NU-RAIL fitting or a CM220 Right Angle Mounting Bracket. Alternatively, the 024A can be attached to the top of our stainless-steel tripods via the CM216 Sensor Mounting Kit. The CM216 extends 4 in. above the mast of a stainless-steel CM110, CM115, or CM120 tripod.

Datalogger Considerations

The 024A uses one single-ended input channel on the datalogger. An excitation channel is required but due to the high impedance of the 024A, can be shared with other high impedance sensors.

Programming

The 024A is read by the BrHalf instruction in CRBasic and by Instruction 4 (Excite-Delay-Single-ended Measurement) in Edlog. The measurements are typically processed for output with the Wind Vector instruction (not present in the CR500 or CR9000).

Compatible Contemporary Dataloggers

CR200(X) Series CR800/CR850 CR1000 CR3000 CR5000 CR7X CR9000X

Compatible Retired Dataloggers

CR500 CR510 CR10 CR10X 21X CR23X CR9000

Resources and Links

Ships With

(1) #1124 Pipe w/ #493 screw

(1) NIST Traceable Calibration Certificate & MIL-STD-45662A

(1) 024ACBL-L Sensor cable w/user specified length

Shipping Weights & Dims

Single Box Shipping Weight:
     5.0 lb plus 0.3 lb per 10'
        of cable
     2.3 kg plus 0.14 kg per
        3.05 m of cable

Single Box Shipping Dimensions:
     24" x 24" x 5"
     61.0 x 61.0 x 12.7 cm